Hemoclips For Gi Bleed
video
Hemoclips For Gi Bleed

Hemoclips For Gi Bleed

A hemoclips for gi bleed is a metallic mechanical device used in endoscopy in order to close two mucosal surfaces without the need for surgery and suturing. Its function is similar to a suture in gross surgical applications, as it is used to join together two disjointed surfaces, but, can be applied through the channel of an endoscope under direct visualization. Endoclips have found use in treating gastrointestinal bleeding (both in the upper and lower GI tract), in preventing bleeding after therapeutic procedures such as polypectomy, and in closing gastrointestinal perforations. Many forms of endoclips exist of different shapes and sizes, including two and three prong devices, which can be administered using single use and reloadable systems, and may or may not open and close to facilitate placement.

Description

Features:

Gastrointestinal bleeding

hemoclips for gi bleed have found a primary application in hemostasis (or the stopping of bleeding) during endoscopy of the upper (through gastroscopy) or lower (through colonoscopy) gastrointestinal tract Many bleeding lesions have been successfully clipped, including bleeding peptic ulcers Mallory-Weiss tears of the esophagus Dieulafoy's lesions. stomach tumours, and bleeding after removal of polyps. Bleeding peptic ulcers require endoscopic treatment if they show evidence of high risk stigmata of re-bleeding, such as evidence of active bleeding or oozing on endoscopy or the presence of a visible blood vessel around the ulcer. The alternatives to endoscopic clipping of peptic ulcers are thermal therapy (such as electrocautery to burn the vessel causing the bleeding), or injection of epinephrine to constrict the blood vessel. Comparative studies between endoclips and thermal therapy make the point that endoclips cause less trauma to the mucosa around the ulcer than electrocautery, but no definitive advantage to either approach has reached consensus by gastroenterologists.


Other applications


An ulcer seen after polypectomy (left) with a visible vessel suggesting recent bleeding is successfully closed with two endoclips (right)

Endoclips have also found an application in preventing bleeding when performing complicated endoscopic procedures. For example, prophylactic clipping of the base of a polyp has been found to be useful in preventing post-polypectomy bleeding, especially in high-risk patients or patients on anticoagulant medications. In addition, clips can be used to close gastrointestinal perforations that may have been caused by complicated therapeutic endoscopy procedures, such as polypectomy, or by the endoscopic procedure itself. Clips have also been used to secure the placement of endoscopic feeding tubes,and to orient the bile duct to assist with endoscopic retrograde cholangiopancreatography, a procedure used to image to bile duct.


Safety

Endoclips have been seen to dislodge between 1 and 3 weeks from deployment, although lengthy clip retention intervals of as high as 26 months have been reported. Endoclips are believed to be safe and no major complications (such as perforation or impaction) have been reported with them, although concern has been raised about blocking the outflow of the bile duct if clips are deployed in the duodenum.



Main Specification:

123

Part No.

Length cm

Opening mm

Coated Plastic

Channel mm

Handle Type

SD-02-165-9

165

9

NO

2.8

Rotatable

SD-02-195-9

195

9

NO

2.8

Rotatable

SD-02-230-9

230

9

NO

2.8

Rotatable

SD-02-165-9C

165

9

YES

2.8

Rotatable

SD-02-195-9C

195

9

YES

2.8

Rotatable

SD-02-230-9C

230

9

YES

2.8

Rotatable

SD-02-165-11

165

11

NO

2.8

Rotatable

SD-02-195-11

195

11

NO

2.8

Rotatable

SD-02-230-11

230

11

NO

2.8

Rotatable

SD-02-165-11C

165

11

YES

2.8

Rotatable

SD-02-195-11C

195

11

YES

2.8

Rotatable

SD-02-230-11C

230

11

YES

2.8

Rotatable

SD-02-165-13

165

13

NO

2.8

Rotatable

SD-02-195-13

195

13

NO

2.8

Rotatable

SD-02-230-13

230

13

NO

2.8

Rotatable

SD-02-165-13C

165

13

YES

2.8

Rotatable

SD-02-195-13C

195

13

YES

2.8

Rotatable

SD-02-230-13C

230

13

YES

2.8

Rotatable

SD-02-165-16

165

16

NO

2.8

Rotatable

SD-02-195-16

195

16

NO

2.8

Rotatable

SD-02-230-16

230

16

NO

2.8

Rotatable

SD-02-165-16C

165

16

YES

2.8

Rotatable

SD-02-195-16C

195

16

YES

2.8

Rotatable

SD-02-230-16C

230

16

YES

2.8

Rotatable



Hot Tags: hemoclips for gi bleed, China, suppliers, manufacturers, factory, customized, wholesale, cheap, buy discount, made in China